Arrowhead Brass 490V Series Faucet Leaking Out Of Spout When Shut Off

Click Here to view the Arrowhead Brass 490V Series Faucet Parts

     If your 490V Arrowhead Brass faucet is leaking out of the spout when turned off, that could mean one of two things. First, the seal on the end of the stem has went bad and isn't seating all of the way allowing water to drip through. If this is the case, you can replace the seal on the end of the stem to fix the issue. The seal comes in the PK1000 stem seal kit

     However, If your faucet has been leaking for a long period of time, meaning months or longer, it could have pierced the seat in the faucet. This happens when the faucet is under pressure for too long. If this is the case, the faucet will have to be replaced. 

See below for help finding the correct stem
See below for help finding the correct stem

See below for the different faucet connection types
See below for help finding the correct stem